bing tracking image
Q & A Icon

Magnetic Door Switch for Kwikee RV Steps that is Normally Closed

Question:

Very confused by the normally open NC question. When I disconnected the power to my switch it retracted the step. My switch has been bad for a long time and step stays out. I was surprised to see when I broke the circuit my step retracted in under camper. Does this mean I have a NO or NC ? Help

0

Expert Reply:

The "normal" part of the normally open or normally closed wording in the switch descriptions has to do with which condition the circuit needs to be in for the step to close. Since when you opened the circuit the step finally retracted that means the switch setup you have is normally closed. So for a replacement switch you'd need the # LC379400.

expert reply by:
0
Jameson C

Products Referenced in This Question


Product Page this Question was Asked From


Q & A Icon

Similar Expert Q&A Pages

See More Q&A Expert Answers >>